INSTALLATION AND OPERATING INSTRUCTIONS
GOLDEN BLOUNT
SUPER-FIRE
MODEL SF3624-TV TOP-VENT FIREPLACE
CSA APPROVED FOR NATURAL GAS OR PROPANE GAS
IMPORTANT! Read all instructions carefully before starting
installation. Failure to follow these instructions may result in
property damage, personal injury or possible loss of life.
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL
GAS:


do not use any phone in your


from a neighbor’s phone. Follow the
gas supplier’s instructions.

supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
The Flue Damper must be in the
full open position when burning the
gas logs.
This fireplace is to be burned only
with the gas log set supplied with the
fireplace. Burning other items could
cause a fire hazard or injury.
For best results, Natural Gas pressure
should be 7" to 12" W.C. and 11" W.C.
for Propane Gas.
To simulate real wood burning, the gas
burner is designed to burn a yellow
flame. It is normal for the logs to soot-
up. The soot can be easily removed
with a vacuum cleaner or soft brush.
Check the label on the firebox to
assure the proper gas type. Never
use anything but the correct gas type
for your fireplace.
This appliance complies with National
Safety and is tested and listed to ANSI
Z21.50b - 2009 as Vented Gas fireplaces.
Installation must conform to local codes.
In the absence of local codes, installation
must conform with the current National
Fuel Gas Code, ANSI Z223.1.
5/13
MANUFACTURED BY:
4301 WESTGROVE DRIVE
ADDISON TX. 75001
INSTALLER/CONSUMER RETAIN THIS APPLIANCE
MANUAL WITH THE INSTALLED APPLIANCE
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - SUPER-FIRE

INSTALLATION AND OPERATING INSTRUCTIONSGOLDEN BLOUNTSUPER-FIREMODEL SF3624-TV TOP-VENT FIREPLACECSA APPROVED FOR NATURAL GAS OR PROPANE GASIMPORTANT!

Page 2

10EXHAUST DIVERTER INSTALLATIONThe Exhaust Diverter prevents exhaust gasses from entering the room.1. Locate screws attached to front side top of int

Page 3 - INTERIOR VIEW

11LOG PLACEMENT FOR MODEL# SF3624TBF LOG SET1234567Placement Instructions Illustration above. It

Page 4

12OPTIONAL GLASS DOOR INSTALLATION1. INSTALL GB DOOR TRACKS AND HINGE SPRINGS AS ILLUSTRATED IN FIGURE 1 USING 6 SCREWS IN KIT. 2. SCREW HANDLES ON

Page 5

13OPERATING GUIDELINES (CONT’D)When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubrican

Page 6 - INSTALLATION INSTRUCTIONS

14FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OREXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,

Page 7 - Figure 7.1

15TO TURN OFF GAS TO APPLIANCE1. Open valve access door panel2. Turn knob clockwise to pilot position then depress and continue tu

Page 8 - Gas Log Installation

16TROUBLE SHOOTING (MILLIVOLT MODEL)With proper installation and maintenance, your new Gas Fireplace should provide years of trouble-free service. If

Page 9

17TROUBLE SHOOTING (CONT’D) SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION2. Pilot will not stay lit A. Defective pilot 1. Check pilot, flame must a

Page 10 - EXHAUST DIVERTER INSTALLATION

18TROUBLE SHOOTING (CONT’D) SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION3. Pilot burning, no A. Damper control lever in 1. Set damper control lever

Page 11 - Placement Instructions

19TO TURN OFF GAS TO APPLIANCEUpon completing the gas line connection, a small amount of air will be in the lines. When rst lighting the pilot light,

Page 12 - 

2TABLE OF CONTENTSSECTIONLayout Options ...

Page 13 - HANDLE ONLY WHEN COOL

20WIRING DIAGRAM (STP-SPARK TO PILOT MODEL)FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EX

Page 14 - GAS VALVE

21LIGHTING INSTRUCTIONS ELEC. SPARK TO PILOT1. “STOP” Read the safety information on page 11.2. Set the switch to “OFF”.3. Remove batteries from ba

Page 15

22LPG (PROPANE) WARNING (CONT’D) IMPORTANT: Always keep the appliance area clear and free from combustible materials, gasoline and other flammable vap

Page 16

23TROUBLE SHOOTING (CONT’D)SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTIONPilot will not stay lit 1. Loose wiring on ignitor wire to ignition module and/o

Page 17 - TROUBLE SHOOTING (CONT’D)

242019181716REPLACEMENT PARTS232512349786515152411121314222110ITEM  DESCRIPTION ITEM  DESCRIPTION1 TV-101 Gas Valve - N/G 17 TV-117 Middle

Page 18

25TWO YEAR LIMITED WARRANTYTHIS WARRANTY IS LIMITED TO TOP-VENT GAS FIREPLACES MANUFACTURED AND ASSEMBLED BY GOLDEN BLOUNT.IF GOLDEN BLOUNT FINDS THAT

Page 19 - Figure 10

3SF3624-TV TOP-VENT FIREPLACEINTERIOR VIEWPan BurnerOutside AirControl KnobDamper ControlLeverPilot LightOn/Off SwitchStand OffsOutside Air PortDamper

Page 20 - Flame SenSor

4BUILDING CODES AND SAFETY STANDARDSThe design of this FIREPLACE ACCESSORY has been tested and is listed with CSA INTERNATIONAL in accordance with THE

Page 21 - LPG (PROPANE) WARNING

5GAS PIPING AND GAS PRESSURE REQUIREMENTSAll gas piping must be installed to comply with local codes, or, in the absence of local codes, with the late

Page 22

6INSTALLATION INSTRUCTIONSIn planning the installation for the fireplace it is necessary to determine where the unit is to be installed, the routing of

Page 23

7Installing Chimney/Vent SystemModel SF3624TV is approved to be used with 8" B-Type Gas Vent or 8" class-A All Fuel Chimney. Under most cond

Page 24

8Connecting the Gas LineConsult local building codes before gas line installation. This gas fireplace is designed to accept a 3/8" male flare fittin

Page 25 - TWO YEAR LIMITED WARRANTY

9INSTALLATION INSTRUCTIONSREFRACTORY BRICK PANELS, DOWNDRAFT DIVERTER,AND EXHAUST DIVERTERSF3624 SUPERFIRE FIREPLACEThis model Golden Blount top vent